ASTM A193 B7 All Threaded Stud Bolts

ASTM A193/A193M B7 All Threaded Stud Bolts

API 6A 6D Flange Valve Wellhead ASME/ANSI Flange All Thread Stud Bolts

Alloy steel bolting for pressure vessels, valves, flanges, and fittings for high temperature or high pressure service, or other special purpose applications.

Standard: IFI-136, ASME B16.5, DIN976

Inch Size: 1/4”-4” with various lengths

Metric Size: M6-M100 with various lengths

Other Available Grade: ASTM A193/A193M B7, B7M, B16, B8 Class 1 & 2, B8M Class 1 & 2; ASTM A320/A320M L7, L7M, L43, B8 Class 1 & 2, B8M Class 1 & 2, and so on.

Finish: Plain, Black Oxide, Zinc Plated, Zinc Nickel Plated, Cadmium Plated, PTFE etc.

Packing: Bulk about 25 kgs each carton, 36 cartons each pallet

Advantage: High Quality and Strict Quality Control, Competitive Price,Timely Delivery; Technical Support, Supply Test Reports

Please feel free to contact us for more details.

ASTM A193

Scope

Originally approved in 1936, this specification is heavily utilized in petroleum and chemical construction applications.  The ASTM standard covers alloy steel and stainless steel bolting materials for high temperature service. This specification includes fasteners intended for use in pressure vessels, valves, flanges, and fittings. Although, this material is often available in national coarse (UNC) thread pitches, if being used in traditional applications, threads are specified 8 threads per inch (tpi) for diameters above one inch.

Below is a basic summary of a few of the common grades. ASTM A193 covers a number of other standard specifications not covered in this description including B5, B6, and B16.

Grades

B7 Alloy steel, AISI 4140/4142 quenched and tempered
B8 Class 1 Stainless steel, AISI 304, carbide solution treated.
B8M Class 1 Stainless steel, AISI 316, carbide solution treated.
B8 Class 2 Stainless steel, AISI 304, carbide solution treated, strain hardened
B8M Class 2 Stainless steel, AISI 316, carbide solution treated, strain hardened

Mechanical Properties

Grade Size Tensile ksi, min Yield, ksi, min Elong, %, min RA % min
B7 Up to 2-1/2 125 105 16 50
2-5/8 - 4 115 95 16 50
4-1/8 - 7 100 75 18 50
B8 Class 1 All 75 30 30 50
B8M Class 1 All 75 30 30 50
B8 Class 2 Up to 3/4 125 100 12 35
7/8 - 1 115 80 15 35
1-1/8 - 1-1/4 105 65 20 35
1-3/8 - 1-1/2 100 50 28 45
B8M Class 2 Up to 3/4 110 95 15 45
7/8 - 1 100 80 20 45
1-1/8 - 1-1/4 95 65 25 45
1-3/8 - 1-1/2 90 50 30 45

Recommended Nuts and Washers

Bolt Grade Nuts Washers
B7 A194 Grade 2H F436
B8 Class 1 A194 Grade 8 SS304
B8M Class 1 A194 Grade 8M SS316
B8 Class 2 A194 Grade 8 SS304
B8M Class 2 A194 Grade 8M SS316

Strain hardened nuts available as a supplementary requirement

Testing Lab

Workshop

Warehouse


  • ASTM A193 B7 All Threaded Stud Bolts Related Video:



    Goodgood an ISO 9001:2008 certified company Manufacturers and Exporters of Spring Channel Nuts,strut support system, Strut Channel Bracketry, strut channel fittings, Ring Hangers channel nuts, Pipe Clamps, strut channel brackets, Clevis Hangers, thread rods thread bars, Beam Clamps, tie rods coil rods, Cantilever Arms, Unistrut Channels, Channel Accessories, Threaded Rods, threaded Bars studs, Coil Rods, unistrut channel brackets manufacturers, exporters, suppliers from india punjab ludhiana, www.strutnfittings.com mobile +918283916900, +919815416900 exports@strutnfittings.com



    Earlier video indicating the issue – https://www.youtube.com/watch?v=Tz02UNj0pkM

    The cutoff shield/metal plate was rubbing against the bent plate and was not getting pulled down when the solenoid was energized. We used a needle nose plier to pull the bent plate off a little bit and now the plate does not rub. Works fine. We used a 9V battery + 2 AAA 1.5V Duracells since the 9V battery was almost dead! If you have this issue, take care while using the pliers not to damage the solenoid assembly while pulling the bent plate.

    This mechanism clearly needs an improvement from the Morimoto guys. The pivoting point of the plate at the right side has a small lateral (forward-aft) movement which has to be restricted. If this is done, the plate will not move back and forth but only top and bottom. Another improvement that can be done is to have the solenoid connector facing the rear instead of the front. Not sure why it was designed this way. Instead of rivets, screws can be used to hold the lens to the projector cast casing. The high-end FX-R and the low-end Mini H1 have screws! Only the Mini D2S has rivets.