Din6915 10V Hex Nuts for High-Strength Structural bolting Dimension Standard: DIN6915 Metric Size: M12-M36 Material Grade: ISO 898-2 class 10 Finish: Plain, Black Oxide, Zinc Plated, Hot Dipped Galvanized, etc. Packing: Bulk about 25 kgs each carton, 36 cartons each pallet Advantage: High Quality, Competitive Price, Timely Delivery,Technical Support, Supply Test Reports Please feel free to contact us for more details.    

  • Factory wholesale DIN6915 10HV Structural nuts for Canada Importers Related Video:



    Departmental Procedures & Guidelines for Inspections, Certifications, Load Testing, Repairs & Painting of Fire Escapes
    Inspections by Structural Engineers, Fire Escape Engineers or others acceptable to the Official:
    In layman’s terms, the city official is looking for a registered structural engineer or others qualified and acceptable by the Fire/Code Official to do a Critical Examination in lieu of a Live Load Test (criteria submitted or discussed prior to inspection) and issues written verification and certification that all connections are free of internal rust or rot as well as all original hardware (square head bolts or rivet) are reinforced and or replaced in lieu of Live Load Test. All supports (thru-bolts or cemented) into the wall must be verified and certified in lieu of Live Load Test. A fire escape confidence test and tag must be submitted if fire escape passed. The report with photos identifying violations for repairs must include repair criteria submitted to the official for repair vendor to use as a guide during and with engineer oversight of permitted repairs. A Fire Escape Confidence Test and tags identifying certified condition are then submitted. Recommended cycle for live load testing is 20 yrs after total refurbishment or as required by official.

    Repairs by Ornamental Ironworkers, Welding Companies or others acceptable to the Official:

    In layman’s terms, the city official is looking for a qualified licensed repair vendor to do all work under repair permit (if required) with engineer oversight of repair criteria submitted for approval to the official in lieu of Live Load Test. All connections must be free of internal rust or rot, spot primed and sealed. All worn material repaired and or replaced. All supports into wall reinforced, repaired and certified in a Fire Escape Confidence Test. In lieu of Live Load Test, all square head bolts, rivets and or welded connections must be certified, reinforced and or replaced based on age or condition. All ladders and cantilevers must be balanced and drop 2-3 ft per second, hit the ground and stay down and must lead to a public way. All roof ladders must be secure. No full painting of any fire escape until all spot painted repairs are inspected and certified under engineer oversight and or city official permit sign-off. Full replacement is subject to permits and or possible code upgrade requirements.
    Painting by EPA Licensed Renovators (if lead paint is present) or others acceptable to Official:
    In layman’s terms, the city official is looking for a paint vendor (EPA Certified Renovator if required) to do all work as per EPA Guidelines due to the fact that all fire escapes older than 1978 are presumed to have lead (EPA) unless identified as no lead or low lead by a licensed lead inspector. Entire building will be notified with signage and all precautions shall be taken to collect paint chips at grade. No sandblasting or power assisted scraping without full fire escape encapsulation under EPA Guidelines. All major connection shall be sealed from water intrusion before during or after painting. All escapes should be spot painted every 3-5 yrs and fully painted every 5-10 yrs or as needed or ordered by a Fire/Code Official.
    Fire Escape Codes:
    NFPA Lifesafety Code 101 7.2.8.6.2 The authority having jurisdiction shall be permitted to approve any existing fire escape Stair that has been shown by load test or other satisfactory evidence to have adequate strength.
    For more information please visit our website at https://fireescapeengineers.com or call 866-649-0333
    Fire Escape Engineers is an approved member of the Fire Escape Services Network https://www.fireescpeservices.com and a founding member of the National Fire Escape Association (NFEA) https://www.nationalfireescapeassociation.org



    Check out our tutorial videos (https://goo.gl/MK4JWp ). You will discover the world of Ambrovit screws and find the ons that fit your needs.
    All rights reserved. Unauthorized reproduction, copying, distribution or any other use of the whole or any part of the contents of this portal is strictly prohibited.

    The hexagonal head, flat washer drilling screws TE FR are required for fixing sheet plating on metal parts. They do not require drilling, thanks to their self-drilling tip, and therefore considerably reduce application times. They are made in carbon steel with galvanized finish, are certified GOST R and comply with the standards DIN 7504-K, UNI 8117, ISO 15480.
    The self- drilling screws are available in stock, in more than 60 items.

    Ambrovit Bolts and Screws

    The Ambrovit company, set up in 1997, is today a leading player in Europe in fastening systems.
    The wide range of Ambrovit bolts and screws , that can be viewed on the online catalogue (link), is always available in our wide warehouse, where over 44.000* products pallets can be stored.
    The certifications D.o.P, GOST R, ETA CE of the Trento University testify the quality and reliability of Ambrovit, offering deliveries throughout Europe in 24/48 hours.

    To learn more about Ambrovit and its products, visit its website www.ambrovit.com