Departmental Procedures & Guidelines for Inspections, Certifications, Load Testing, Repairs & Painting of Fire Escapes
Inspections by Structural Engineers, Fire Escape Engineers or others acceptable to the Official:
In layman’s terms, the city official is looking for a registered structural engineer or others qualified and acceptable by the Fire/Code Official to do a Critical Examination in lieu of a Live Load Test (criteria submitted or discussed prior to inspection) and issues written verification and certification that all connections are free of internal rust or rot as well as all original hardware (square head bolts or rivet) are reinforced and or replaced in lieu of Live Load Test. All supports (thru-bolts or cemented) into the wall must be verified and certified in lieu of Live Load Test. A fire escape confidence test and tag must be submitted if fire escape passed. The report with photos identifying violations for repairs must include repair criteria submitted to the official for repair vendor to use as a guide during and with engineer oversight of permitted repairs. A Fire Escape Confidence Test and tags identifying certified condition are then submitted. Recommended cycle for live load testing is 20 yrs after total refurbishment or as required by official.
Repairs by Ornamental Ironworkers, Welding Companies or others acceptable to the Official:
In layman’s terms, the city official is looking for a qualified licensed repair vendor to do all work under repair permit (if required) with engineer oversight of repair criteria submitted for approval to the official in lieu of Live Load Test. All connections must be free of internal rust or rot, spot primed and sealed. All worn material repaired and or replaced. All supports into wall reinforced, repaired and certified in a Fire Escape Confidence Test. In lieu of Live Load Test, all square head bolts, rivets and or welded connections must be certified, reinforced and or replaced based on age or condition. All ladders and cantilevers must be balanced and drop 2-3 ft per second, hit the ground and stay down and must lead to a public way. All roof ladders must be secure. No full painting of any fire escape until all spot painted repairs are inspected and certified under engineer oversight and or city official permit sign-off. Full replacement is subject to permits and or possible code upgrade requirements.
Painting by EPA Licensed Renovators (if lead paint is present) or others acceptable to Official:
In layman’s terms, the city official is looking for a paint vendor (EPA Certified Renovator if required) to do all work as per EPA Guidelines due to the fact that all fire escapes older than 1978 are presumed to have lead (EPA) unless identified as no lead or low lead by a licensed lead inspector. Entire building will be notified with signage and all precautions shall be taken to collect paint chips at grade. No sandblasting or power assisted scraping without full fire escape encapsulation under EPA Guidelines. All major connection shall be sealed from water intrusion before during or after painting. All escapes should be spot painted every 3-5 yrs and fully painted every 5-10 yrs or as needed or ordered by a Fire/Code Official.
Chuyên sản xuất: TY REN/TY TREO/TY RĂNG/THANH REN/ TY TREO mạ kẽm M6, M8, M10, M12, M16 — (High quality Galvanized Thread Rod) 1m, 2m, 3m, đạt tiêu chuẩn JIS B 1051 — JAPAN & DIN 975 & DIN 976- Đức, Đai treo /Cùm treo, Đai treo 2 mảnh (Pipe hanger/Conduit Clamp), tắc kê đạn, Đai treo Omega, cùm omega, Cùm Ubolt, Cùm Ubolt lá (U Bolts) Gía đỡ cơ điện (M&E/Mechanical Fixings, Fasteners and Spring steel Supports) Cùm treo ống / Kẹp treo ty & ống / Kẹp treo ống thép luồn dây điện, ống PCCC/ HVAC (Steel conduit hanger/Pipe hanger/Clevis Hanger), Kẹp xà gồ/ Kẹp dầm thép (Beam Clamp/Suspending Clamp/C-Clamp), Thanh chống đa năng (Unistrut Channel/ Strut/ C-Channel/ Double Unistrut profile ), Đai ốc lò xo cho thanh chống đa năng (Long spring nut), Tay đỡ đơn (Cantilever Arm), U cùm ( U bolts), Tắc kê đạn (Drop In Anchor), Đai treo (bát treo) cho hệ thống điện nhẹ M&E / HVAC/PCCC /Điều hoà không khí cho toà nhà cao tầng và nhà máy sản xuất công nghiệp tại
CÔNG TY TNHH THIẾT BỊ ĐIỆN CÔNG NGHIỆP CÁT VẠN LỢI
Văn Phòng: 504 Lê Quang Định, P.1, Quận Gò Vấp, TP Hồ Chí Minh
Điện thoại: (84.8) 3588 6496/ 3895 6808/ 2246 4699
Fax: (84.8) 3588 6505
Nhà Máy: 50 Tây Lân, P.Bình Trị Đông A, Q.Bình Tân ,TP.HCM
Website: www.catvanloi.com E-mail: sales@catvanloi.com
Phòng KD & Dự án: Ms Hiền 0902377537 / 08-22464699