What is a transformer?
A transformer is an electrical device that transfers electrical energy from one circuit to another by electromagnetic induction (also called transformer action). It is most often used to step up or step down voltage levels.
The following are the basic components of a transformer.
1. Laminated core
2. Windings
3. Insulating Materials
4. Transformer oil
5. Tap changer
6. Conservator
7. Breather
8. Cooling tubes
9. Buchholz Relay
10. Explosion vent
Core :
Core is used to support the windings in the transformer. It also provides a low reluctance path to the flow of magnetic flux. It is made up of laminated soft iron core in order to reduce eddy current loss and Hysteresis loss. The composition of a transformer core depends on such factors as voltage, current, and frequency.
Windings
There are two windings wound over the transformer core which are insulated from each other. Windings consists of several turns of copper coils bundled together an each bundles are connected in series to form a winding.
High voltage windings are made up of copper coil. The number of turns in it is the multiple of the number of turns in the low voltage windings. It has copper coils thinner than that of the low voltage windings.
b) Low voltage windings
Low voltage winding has lesser number of turns than that of the high voltage windings. It is made up of the thick copper conductors. This is because the current in the low voltage windings is higher than that of high voltage windings.
Transformer can be supplied from either LV or HV windings based on the requirement.
Tap changer :
The output voltage may vary according to the input voltage and the load. During loaded conditions the voltage on the output terminal fall and during off load conditions the output voltage increases. In order to balance the voltage variations tap changers are used. Tap changers can be either on load tap changer or off load tap changer. In on load tap changers the tapping can be changed without isolating the transformer from the supply and in off load tap changers it is done after disconnecting the transformer. Automatic tap changers are also available.
Transformer oil :
Transformer oil performs two important functions of insulation as well as cooling for the core and coil assembly. Core and windings of the transformer must be completely immersed in the oil. Normally hydrocarbon mineral oils are used as transformer oil. Oil contamination is a serious problem because it robs its dielectric properties and renders it useless as an insulating medium
Bushings :
There are many methods to classify the types of bushings. These classifications are based on practical reasons, which will become apparent in the following discussion in three broad areas.
Bushings can be classified:
1. According to insulating media on ends
2. According to construction
3. According to insulation inside bushing
According to construction bushings are of two types – solid type or bulk type and the capacitance-graded or condenser type.
According to the insulation inside bushing they are classified as – Air-Insulated Bushings, Oil-Insulated or Oil-Filled Bushings, Oil-Impregnated Paper-Insulated Bushings, Resin-Bonded or -Impregnated Paper-Insulated Bushings, Cast-Insulation Bushings, Gas-Insulated Bushings.
Oil Tank:
This part of the transformer contains the assembly of the core and the winding which is immersed in insulation oil.
Follow us on facebook : www.facebook.com/EWC102/
Websit: https://www.jmtornillo.com
Ahora me gustaría presentarle las tuercas cuadradas.
Los estándares son ASME/ANSI B18.2.2 y DIN557, DIN562
Los grados de estándar IFI son SAE J995 Gr.2 y A563 Gr. A, Grados de estándar DIN son Class 4, 5, 6, 8.
este es la tuerca cuadrada de Zincaday este es fabricada en particular.
La tuerca es disponible con el perno cuadrado en aplicación.
Tambien podemos fabricar tuercas hexagonales cuadradas especiales según sus muestras y dibujos
Shanghai Jian y Mei es un proveedor profesional de tuercas de estándar IFI y DIN, por ejemplo tuerca hexagonal pesada, tuerca hexagonal, tuerca cuadrada, tuerca flange, tuerca de bloqueo y Tuercas hexagonales de Acoplamiento etc.
Tenemos tamaños completos de M3 a M100, y 3/16” a 4”.
Los materiales pueden ser acero al carbono, acero de aleación, acero inoxidable y cobre.
Grados disponibles de tuercas son ASTM A563 grado A, grado C, grado DH, ASTM A194 Gr. 2, 2H, 7, 7M,8, 8M, SAE J995 Gr.2, 5,8; CL4, 5, 6, 8, 10, 12.
Los acabados son Zinc, Zinc amarillo, Óxido negro, galvanizado etc.
Tenemos más de ocho años de experiencia exportar tuercas cuadradas al mercado américo y poseemos buena fama, enfíen en nosotros que somos su proveedor fiable de fijación!
No dude en contactarnos en cualquier momento!
Shanghai Jian & Mei Industry and Trade Co., Ltd
Rm.27202, No.295 South Lingyan Road, Pudong,Shanghai,P.R.C, Code:200126
Tel: 0086-21-33328690-8058
Fax: 0086-21-68413263
English Web:www.jm-industry.com Websit: https://www.jmtornillo.com
Contact: Mrs.Xarella Huang
Email: Jminfo@jm-industry.com
Websit: https://www.jm-industry.com